UPSI-2412D Intelligent DC-UPS / 240W / 24V 10A / DIN Rail version / DC-DC
Uninterruptible power supply (DC UPS)
- Supercap or LiFePo4 energy storage
- Regulated output voltage at backup
- Minimum load disconnect
- Battery start function
- Configurable potential-free relay contact for PowerFail
- Intelligent PowerSharing-Function
- USB & RS232 Interface
- Plug&Play - recognized as UPS by operating system
- Extended functionality by UPScom management software
- Timer function
- Shutdown & Reboot function
- 3 years warranty
Quantity | Unit price |
---|---|
1 to 9 | €320.94 * |
From 10 | €288.22 * |
From 50 | €274.41 * |
From 100 | €265.73 * |
*Prices incl. 19% VAT plus shipping costs
Weight: 0.34 kg
Avoid system failures and data loss!
Modular DC emergency power supply with 10A protects against power failure, voltage drops and flicker
The intelligent DC UPS UPSI-2412D for flexible system integration reliably bridges power failures and faults, so that the uninterruptible 24 VDC power supply with up to 10A is guaranteed at the output at all times.
In normal operation, the UPSI-2412D forwards the DC input voltage directly to the output, charges the connected energy storage device in parallel and monitors all relevant parameters, currents and voltages. In the event of a voltage drop or power failure, a MOSFET disconnects the input within a few microseconds and the connected load is supplied without interruption from the energy storage device and the UPSI-2412D provides a constantly regulated DC output voltage.
Flexible use of suitable energy storage
So that the UPSI-2412D can be used flexibly with different storage technologies, three charging methods with individual adjustment of the end-of-charge voltage are implemented: Constant Current, Constant Voltage and Constant Power. The integrated microcontroller (µC) recognizes the type and data of the energy storage so that the charging and discharging parameters can be individually adjusted.
Supercaps (ultracapacitors)
In the area of short and medium bridging times, with the BP-SUC series we offer absolutely maintenance-free supercaps as highly efficient and particularly long-lasting energy storage devices with more than 500,000 charge and discharge cycles.
LiFePO4 battery cells
Lithium-ion technology with high energy density is ideal for longer bridging times. Our high-performance battery packs of the BP-LFP series impress in safety-relevant applications with a high cycle stability (6,000 charging and discharging cycles) and an integrated battery management system (BMS).
Lead batteries
With the UPSI-2412D it is also possible to use selected lead-acid battery storage systems - please contact us, we will be happy to advise you!
Plug & Play for quick and easy installation
The UPSI-2412D has an integrated USB interface for connection to an IPC system and is recognized directly by the operating system as a UPS - without additional drivers or software installation.
Intelligent PowerSharing Function
On the input side, this implemented function ensures that the upstream AC/DC power supply does not have to be oversized, but that the input power is kept constant and appropriately distributed to the load and battery charger. This means that if the load at the output is low, more energy flows into the charger and vice versa.
Battery start function
For mobile applications, the UPSI-2412D has the option of starting the supplied application with a maximum load current of 7 A from the battery, without a mains-side power supply being available or connected. To do this, the 'BS' button is pressed for more than 2 seconds. We recommend the LiFePO4 battery pack BP-LFP-2725 for this purpose.
Relay contact for PowerFail
The functionality and behavior of the 2-pin relay connection in the event of a power failure can be defined using the 'UPSGen2 Configuration' software: 'Normally Open', 'Normally Closed' or 'Shutdown Pulse'. When the relay closes, the resistance between the two pins is ⁓ 0 Ohm, otherwise the contacts are 'Open Load'.
Minimum load detection
In the 'UPSGen2 Configuration' software, the minimum output current to the DC load in UPS battery operation can be set and monitored via the load sensor. If the load at the output falls below this limit value, the energy storage device is automatically disconnected from the charging and control unit after 10 seconds, so that no unnecessary and gradual discharge of the energy storage device can take place. The DC UPS can also be switched off in a defined manner.
'UPSGen2 Configuration' software –
Extended functionality and monitoring
The free 'UPS Gen2 Configuration' software is available for download and is used to setup and parameterize the DC UPS system as well as for real-time monitoring. The UPS and battery status displays include all relevant voltages, currents as well as battery temperature, state of charge (SOC), runtimes and cycles. The pre-programmable parameters include load sensor (mA), shutdown delay, maximum backup time, minimum load capacity before system start, ignition timer and restart delay. Self-sufficient operation is then possible with the set values.
Timer function for controlled system shutdown according to the time specified
The new "Shut Down OS in" parameter can be used to set the time until the computer system is shut down and switched off in the event of a power failure. In addition to the operating system setting with regard to „State Of Charge“ of the energy storage device ("Shut Down OS at SOC"), the new function can now be used to define a specific time for the controlled shutdown in UPS backup mode.
Shutdown & reboot function for IPC systems
In the event of a ‘PowerFail, the DC UPS signals the failure of the supply voltage via the integrated interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. The integrated reboot function of the DC UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by a service employee, e.g. with completely self-sufficient computer systems in inaccessible locations.
DC UPS systems for maximum reliability of 24VDC applications
In the area of uninterruptible power supply, our DC UPS systems can be used in a variety of applications for a wide variety of industries and fields of application: Industry 4.0, automation, medical and laboratory technology, transportation, traffic monitoring, energy, communication, vending, POS / payment systems, security technology, mobile systems and much more.
Customer-specific solutions and adjustments for your individual application are possible on request. We are happy to help!
Avoid system failures and data loss!
Modular DC emergency power supply with 10A protects against power failure, voltage drops and flicker
The intelligent DC UPS UPSI-2412D for flexible system integration reliably bridges power failures and faults, so that the uninterruptible 24 VDC power supply with up to 10A is guaranteed at the output at all times.
In normal operation, the UPSI-2412D forwards the DC input voltage directly to the output, charges the connected energy storage device in parallel and monitors all relevant parameters, currents and voltages. In the event of a voltage drop or power failure, a MOSFET disconnects the input within a few microseconds and the connected load is supplied without interruption from the energy storage device and the UPSI-2412D provides a constantly regulated DC output voltage.
Flexible use of suitable energy storage
So that the UPSI-2412D can be used flexibly with different storage technologies, three charging methods with individual adjustment of the end-of-charge voltage are implemented: Constant Current, Constant Voltage and Constant Power. The integrated microcontroller (µC) recognizes the type and data of the energy storage so that the charging and discharging parameters can be individually adjusted.
Supercaps (ultracapacitors)
In the area of short and medium backup times, with the BP-SUC-D series we offer absolutely maintenance-free supercaps as highly efficient and particularly long-lasting energy storage devices with up to 500,000 charge and discharge cycles.
LiFePO4 battery cells
Lithium-ion technology with high energy density is ideal for longer backup times. Our high-performance battery packs of the BP-LFP-D series impress in safety-relevant applications with a high cycle stability (6,000 charging and discharging cycles) and an integrated battery management system (BMS).
Lead batteries
With the UPSI-2412D it is also possible to use selected lead-acid battery storage systems - please contact us, we will be happy to advise you!
UPS management software 'UPScom'
with intuitive user interface
The software 'UPScom' (freely available for download) allows the connected devices to be shut down and switched off in a controlled manner during a power failure in order to avoid data loss or damage. The responsive WEB UI is called up in a web browser to set and pre-program all parameters of the DC UPS system and for real-time monitoring with state-of-charge indicator. The adjustable parameters include, among other things, load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, notifications by email.
Cross-platform technology
'UPScom' uses the new WebAssembly (WASM) architecture, which runs in most current web browsers. 'UPScom' runs on x86 compatible systems and also on most ARM-64 based systems under Microsoft® Windows and various Linux distributions.
Secure Shutdown & Reboot function for IPC systems
In the event of a "power failure", the UPS signals the failure of the supply voltage via the integrated USB or RS232 interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. A script (batch) can also be executed before the system is shut down in order to process your own application-relevant processes. The integrated reboot function of the DC UPS automatically restarts the supplied IPC after the supply voltage returns, without the need for time-consuming on-site intervention by a service employee, e.g. in the case of completely self-sufficient computer systems at inaccessible locations.
Email messenger service
'UPScom' can be used for various events such as loss of connection to the UPS, system shutdown or power failure. These preventative measures can reduce or eliminate downtime.
Plug & Play for quick and easy installation
The UPSI-2412D has an integrated USB interface for connection to an IPC system and is recognized directly by the operating system as a UPS - without additional drivers or software installation.
Intelligent PowerSharing Function
On the input side, this implemented function ensures that the upstream AC/DC power supply does not have to be oversized, but that the input power is kept constant and appropriately distributed to the load and battery charger. This means that if the load at the output is low, more energy flows into the charger and vice versa.
Battery start function
For mobile applications, the UPSI-2412D has the option of starting the supplied application with a maximum load current of 7 A from the battery, without a mains-side power supply being available or connected. To do this, the 'BS' button is pressed for more than 2 seconds. We recommend the LiFePO4 battery pack BP-LFP-2725D for this purpose.
Relay contact for PowerFail
The functionality and behavior of the 2-pin relay connection in the event of a power failure can be defined using the 'UPSGen2 Configuration' software: 'Normally Open', 'Normally Closed' or 'Shutdown Pulse'. When the relay closes, the resistance between the two pins is ⁓ 0 Ohm, otherwise the contacts are 'Open Load'.
Minimum load detection
In the 'UPSGen2 Configuration' software, the minimum output current to the DC load in UPS battery operation can be set and monitored via the load sensor. If the load at the output falls below this limit value, the energy storage device is automatically disconnected from the charging and control unit after 10 seconds, so that no unnecessary and gradual discharge of the energy storage device can take place. The DC UPS can also be switched off in a defined manner.
DC UPS systems for maximum reliability of 24VDC applications
In the area of uninterruptible power supply, our DC UPS systems can be used in a variety of applications for a wide variety of industries and fields of application: Industry 4.0, automation, medical and laboratory technology, transportation, traffic monitoring, energy, communication, vending, POS / payment systems, security technology, mobile systems and much more.
Customer-specific solutions and adjustments for your individual application are possible on request. We are happy to help!
Output voltage: | 24VDC |
Output power in W: | 240 |
Input voltage: | DC |
Input voltage DC in V: | 24 |
Mounting: | DIN-Rail |
Output current max. convection cooled in A: | 10 |
Feel free to contact us at [email protected].
WEEE-Nr: DE18400369
- 9-pole
- Male-Female
- Length 2000mm
- LiFePO4 battery pack (DIN rail)
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- DIN rail chassis
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- DIN rail chassis
- LiFePO4 battery pack (DIN rail)
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Additional +24VDC output
- Ideal for applications with large monitors
- High efficiency of 84%
- Power cord / IEC-320-C13
- Fits for safety bar BEA series
- 3G 0,75mm², Length: 1800 mm
- For BP-LFP-1375
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- LiFePO4 battery pack
- Extended temperature range -20…+55°C
- Very high storage capability
- Ideal for long-term backups
- 9-pole
- Male-Female
- Length 2000mm
- Universal AC input voltage range
- Ultra slim design
- Operate from -30°C to +70°C with -40°C Cold Start
- Fixation support incl. rubber
- 2 pcs set
- Active PFC with up to 94% efficiency
- Power Boost of 150% up to 7 seconds
- Maritime approvals GL / ABS
- Protective conformal coating on PCBs
- Built-in constant current circuit for reactive loads
- Full power from -10°C to +50°C
- Built-in DC OK relay contact
- Universal AC input voltage range
- Ultra slim design
- Operate from -30°C to +70°C with -40°C Cold Start
- DC UPS with LiFePo battery inside
- Powerful and reliable
- USB and RS232 Interface
- Operating temperature range -20°…+55°C
- DC UPS with LiFePo battery inside
- Powerful and reliable
- USB and RS232 Interface
- Operating temperature range -20°…+55°C
- DC UPS with Supercaps inside
- Maintenance free and durable
- Power-Fail timer function
- Operating temperature range -20°…+70°C
- LiFePO4 battery pack (DIN rail)
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- DC UPS with Supercaps inside
- Operating temperature range -20...+65°C
- Power-fail Timer
- Approved to IEC/EN/UL 61010-1
- DC UPS with Li-Ion battery inside
- Minimum load detection
- Power-fail Timer
- Approved to IEC/EN/UL 61010-1
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- DIN rail chassis
- DC UPS with LiFePo battery inside
- Operating temperature range -20…+50°C
- Power-fail Timer
- With UPScom management software
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- Compact 24V DC-UPS
- Integrated Supercaps - maintenance-free
- UPScom manegment software incl.
- Reboot function
- DC-UPS for lead acid batteries
- Operation temperature range from -20°C to +60°C
- Full corrosion resistant Aluminium chassis
- Low budget UPS solution
- DC-UPS for lead acid batteries
- Zero switch over time from loss of DC input
- Operating temperature range -20°C to +60°C
- Low budget UPS solution
- Flexible DC-UPS for LiFePO4 and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- LiFePO4 battery pack
- Extended temperature range -20…+55°C
- Very high storage capability
- Ideal for long-term backups
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- DC UPS with LiFePo battery inside
- Operating temperature range -20...+55°C
- USB & RS232 Interface
- Incl. UPScom management software
- Compact 24V DC-UPS
- Supercaps - maintenance-free
- Software UPS Control Center
- Extended temperature range
- DC UPS with Supercaps inside
- Operating temperature range -20...+65°C
- USB & RS232 Interface
- Incl. UPScom management software
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- DC UPS with 24V input and 12V output
- SuperCaps as energy storage
- Maintenance-free and fanless
- Interface RS232 & I²C
- DC UPS for use with lead batteries (SLA)
- Suitable for 24 V systems
- Selectable Charging Current
- Outdoor AC/DC UPS for extreme environments in robust aluminium housing
- IP65 protection
- Temperature range -20…+50°C
- IEC/EN 62040-1 certified
- DC UPS for use with lead batteries (SLA)
- Suitable for 24 V systems
- Selectable Charging Current
- DC UPS with 24V input and 12V output
- SuperCaps as energy storage
- Maintenance-free and fanless
- Interface RS232 & I²C
- Compact 12V DC-UPS
- Integrated Supercaps - maintenance-free
- UPScom management software incl.
- Reboot function
- Flexible DC-UPS for LiFePO4 and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- Integrated, space-saving UPS solution
- USB interface
- Reboot function
- Wall bracket available
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+50°C
- Compact 12V DC-UPS
- Supercaps - maintenance-free
- Software UPS Control Center
- Reboot function
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- DIN rail chassis
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+55°C
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+55°C
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- LiFePO4 battery pack (DIN rail)
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- DC UPS with 24V input and 12V output
- SuperCaps as energy storage
- Maintenance-free and fanless
- Interface RS232 & I²C
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium housing
- Operating temperature range -20...+50°C
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- DIN rail chassis
- Active PFC with up to 94% efficiency
- Power Boost of 150% up to 7 seconds
- Maritime approvals GL / ABS
- Universal AC input voltage range
- Ultra slim design
- Operate from -30°C to +70°C with -40°C Cold Start
- Operating temperature up to +60°C
- Sine wave output voltage
- Battery backup time monitoring
- Hawker/Cyclon batteries