UPSI-2406 Intelligent DC UPS / 144W / 24V 6A / Open Frame version / DC-DC
24VDC UPS Open Frame Version
- 24V DC UPS
- For use with long-life LiFePO4 and Supercap battery packs
- Intelligent power sharing
- Regulated output voltage during backup operation
- Min. load disconnect
- Power fail timer
- Battery start function
- External signal shutdown
- USB & RS232 Interface
- Plug&Play - recognized as UPS by operating system
- Extended functionality by UPScom management software
- Reboot function
- Fuel gauge
- 3 years warranty
Quantity | Unit price |
---|---|
1 to 9 | €194.80 * |
From 10 | €174.93 * |
From 50 | €166.48 * |
From 100 | €161.24 * |
*Prices incl. 19% VAT plus shipping costs
Weight: 0.1 kg
Avoid system downtimes and data loss!
Modular DC UPS system protects against power failure, voltage fluctuations and flicker
The DC UPS charging and control unit UPSI-2406 for modular and flexible system integration reliably bridges power failures and faults, so that an uninterruptible 12VDC power supply is ensured at the output at all times. LiFePO4 cells (BP-LFP) or Supercaps (BP-SUC) are available for energy storage:
10-year battery storage with LiFePO4 cells for long bridging times
Lithium-ion technology with high energy density is ideal for longer bridging times. Our battery packs with LiFePO4 cells convince in safety-relevant applications with a high cycle stability (6,000 charging and discharging cycles) and an integrated battery management system (BMS). The BMS monitors and controls the entire charging and discharging process of each battery cell and thus optimizes the service life and operational reliability of the energy storage device. The integrated cell balancing ensures that all cells are charged evenly so that the full capacity of the battery pack can be used over the long term.
Maintenance-free Supercaps for short and medium bridging times
In the area of short and medium bridging times, absolutely maintenance-free Supercaps (ultracapacitors) are available as highly efficient and particularly long-lasting energy storage devices with more than 500,000 charge and discharge cycles. In contrast to batteries, which store energy via a detour through a chemical reaction, Supercaps are based on electrophysical principles and are charged and ready for use within a very short time. Our Supercap energy storage devices have an integrated control and protection circuit as well as a Connect / Disconnect Power function.
Intelligent charging and control unit UPSI
The compact charging and control module Bicker UPSI is connected to the appropriate energy storage device (LiFePO4 or Supercaps) via two cables. In addition to the energy transmission line (BAT PWR), all relevant operating data of the energy storage device is continuously monitored and controlled on the data line (BAT DATA) via the I2C interface. When changing the energy storage, which is even possible during operation ('hot swapping'), a battery type ID authentication is carried out so that the appropriate charging and discharging parameters can be set automatically on the DC UPS.
PowerSharing function
On the input side, the intelligent 'PowerSharing' function ensures that the upstream AC/DC power supply does not have to be overdimensioned, but that the input power is kept constant and appropriately distributed to the load and battery charger. This means that when there is a low load at the output, more energy flows into the charger and vice versa.
Minimum load detection
The 'minimum load detection' of the UPSI control unit monitors the output load to be supplied from the energy storage in backup mode (battery mode). If the load at the output falls below a certain limit value, the energy storage device is automatically disconnected from the charging and control unit, so that the energy store is not unnecessarily emptied by the DC UPS electronics. In addition, the minimum load detection ensures that the computer system has been shut down properly after an initiated shutdown process, before the reboot function initiates the restart of the system.
Integrated shutdown & reboot function for IPC systems
In the event of a "PowerFail", the DC UPS signals the failure via the integrated interface, so that a controlled shutdown of the computer system is initiated and valuable data can be saved. The integrated reboot function of the DC UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by a service employee, e.g. with completely self-sufficient computer systems in inaccessible locations.
UPS data monitoring and preprogramming for autonomous operation
USB and RS232 interfaces are available for data communication with controllers or PC-based systems. With the help of the free HID battery parameter software, settings on the DC UPS can be easily made. The software can be downloaded free of charge. In addition, an extensive set of commands enables the direct reading of sensor values and the setting of parameters. The continuous recording of operating data allows "Data Monitoring" in real time. The open communication protocol offers system developers individual options for connecting to their own system.
DC UPS systems for maximum reliability of 24VDC applications
In the field of uninterruptible power supply, our DC UPS systems can be used in a variety of applications for a wide range of industries: Industry 4.0, automation, medical and laboratory technology, transportation, traffic monitoring, energy, communication, vending, POS / payment systems, security technology and many more.
Customer-specific solutions and adjustments for your individual application are possible on request. We are happy to help!
Avoid system downtimes and data loss!
Modular DC UPS system protects against power failure, voltage fluctuations and flicker
The DC UPS charging and control unit UPSI-2406 for modular and flexible system integration reliably bridges power failures and faults, so that an uninterruptible 24VDC power supply is ensured at the output at all times. LiFePO4 cells (BP-LFP) or Supercaps (BP-SUC) are available for energy storage:
10-year battery storage with LiFePO4 cells for long bridging times
Lithium-ion technology with high energy density is ideal for longer bridging times. Our battery packs with LiFePO4 cells convince in safety-relevant applications with a high cycle stability (6,000 charging and discharging cycles) and an integrated battery management system (BMS). The BMS monitors and controls the entire charging and discharging process of each battery cell and thus optimizes the service life and operational reliability of the energy storage device. The integrated cell balancing ensures that all cells are charged evenly so that the full capacity of the battery pack can be used over the long term.
Maintenance-free Supercaps for short and medium bridging times
In the area of short and medium bridging times, absolutely maintenance-free Supercaps (ultracapacitors) are available as highly efficient and particularly long-lasting energy storage devices with up to 500,000 charge and discharge cycles. In contrast to batteries, which store energy via a detour through a chemical reaction, Supercaps are based on electrophysical principles and are charged and ready for use within a very short time. Our Supercap energy storage devices have an integrated control and protection circuit as well as a Connect / Disconnect Power function.
UPS management software 'UPScom'
with intuitive user interface
The software 'UPScom' (freely available for download) allows the connected devices to be shut down and switched off in a controlled manner during a power failure in order to avoid data loss or damage. The responsive WEB UI is called up in a web browser to set and pre-program all parameters of the DC UPS system and for real-time monitoring with state-of-charge indicator. The adjustable parameters include, among other things, load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, notifications by email.
Cross-platform technology
'UPScom' uses the new WebAssembly (WASM) architecture, which runs in most current web browsers. 'UPScom' runs on x86 compatible systems and also on most ARM-64 based systems under Microsoft® Windows and various Linux distributions.
Secure Shutdown & Reboot function for IPC systems
In the event of a "power failure", the UPS signals the failure of the supply voltage via the integrated USB or RS232 interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. A script (batch) can also be executed before the system is shut down in order to process your own application-relevant processes. The integrated reboot function of the DC UPS automatically restarts the supplied IPC after the supply voltage returns, without the need for time-consuming on-site intervention by a service employee, e.g. in the case of completely self-sufficient computer systems at inaccessible locations.
Email messenger service
'UPScom' can be used for various events such as loss of connection to the UPS, system shutdown or power failure. These preventative measures can reduce or eliminate downtime.
Intelligent charging and control unit UPSI
The compact charging and control module Bicker UPSI is connected to the appropriate energy storage device (LiFePO4 or Supercaps) via two cables. In addition to the energy transmission line (BAT PWR), all relevant operating data of the energy storage device is continuously monitored and controlled on the data line (BAT DATA) via the I2C interface. When changing the energy storage, which is even possible during operation ('hot swapping'), a battery type ID authentication is carried out so that the appropriate charging and discharging parameters can be set automatically on the DC UPS.
PowerSharing function
On the input side, the intelligent 'PowerSharing' function ensures that the upstream AC/DC power supply does not have to be overdimensioned, but that the input power is kept constant and appropriately distributed to the load and battery charger. This means that when there is a low load at the output, more energy flows into the charger and vice versa.
Minimum load detection
The 'minimum load detection' of the UPSI control unit monitors the output load to be supplied from the energy storage in backup mode (battery mode). If the load at the output falls below a certain limit value, the energy storage device is automatically disconnected from the charging and control unit, so that the energy store is not unnecessarily emptied by the DC UPS electronics. In addition, the minimum load detection ensures that the computer system has been shut down properly after an initiated shutdown process, before the reboot function initiates the restart of the system.
DC UPS systems for maximum reliability of 24VDC applications
In the field of uninterruptible power supply, our DC UPS systems can be used in a variety of applications for a wide range of industries: Industry 4.0, automation, medical and laboratory technology, transportation, traffic monitoring, energy, communication, vending, POS / payment systems, security technology and many more.
Customer-specific solutions and adjustments for your individual application are possible on request. We are happy to help!
Output voltage: | 24VDC |
Input voltage: | DC |
Input voltage DC in V: | 24 |
Output current max. convection cooled in A: | 6 |
Mounting: | Open Frame |
Output power in W: | 144 |
Feel free to contact us at [email protected].
WEEE-Nr: DE18400369
- LiFePO4 battery pack
- Extended temperature range -20…+55°C
- Very high storage capability
- Ideal for long-term backups
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- Intelligent deep discharge protection
- For BP-LFP-1025(S) and BP-LFP-1325(S)
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- For BP-LFP-1375
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- LiFePO4 battery pack
- Extended temperature range -20…+55°C
- Very high storage capability
- Ideal for long-term backups
- To improve EMC characteristics
- Quality marks: UL, VDE, CQC (to filter)
- Rated current: Up to 6 A
- Output: JST pitch 3.96mm (L, N) / M5 (PE)
- Length 600 mm
- Ends open
- PU: 1 piece
- 150 Watt continuous power
- 2"x4" form factor
- Efficiency up to 91%
- Top price performance
- Desktop adapter for industrial applications
- IEC/EN/UL 62368-1
- CEC Level VI & Tier 2 conform
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- Intelligent deep discharge protection
- Low profile design : 30mm height
- Wide operating temp -30°C ~ 70°C (Support -40°C cold start)
- IEC/EN/UL 62368-1 certified
- To improve EMC characteristics
- Quality marks: UL, VDE, CQC (to filter)
- Rated current: Up to 6 A
- Output: JST pitch 3.96mm (L, N) / M4 (PE)
- Connection cable for UPSIC-2403 / UPSIC-1205 / DC2412-UPS(-LD)
- Twisted pair connector wire open end
- Length 300mm
- Designed for industrial and medical applications
- 200W output with forced air cooling
- 140W output with conduction cooling
- IEC/EN/UL 60601-1 / 62368-1 certified
- Length 620 mm
- Ends open
- Compact 24V DC-UPS
- Supercaps - maintenance-free
- Software UPS Control Center
- Extended temperature range
- Reboot function for
- DC2412-UPS(LD) - UPSIC-2403 - UPSIC-1205
- Plug-In solution
- Compact dimensions
- Length 500 mm (AWG 18)
- Ends open
- PU: 1 piece
- Length 500 mm (AWG 18)
- Ends open
- PU: 1 piece
- Length 600 mm
- Ends open
- PU: 1 piece
- Supercap storage for 12V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Adapter for medical applications
- Class 2 equipment - without PE
- Compliant with ErP and CEC level V
- Compact 24V DC-UPS
- Supercaps - maintenance-free
- Software UPS Control Center
- Extended temperature range
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- LiFePO4 battery pack
- Extended temperature range -20…+55°C
- Very high storage capability
- Ideal for long-term backups
- DC UPS with Li-Ion battery inside
- Minimum load detection
- Power-fail Timer
- Approved to IEC/EN/UL 61010-1
- DC UPS with Supercaps inside
- Operating temperature range -20...+65°C
- Power-fail Timer
- Approved to IEC/EN/UL 61010-1
- Flexible DC-UPS for LiFePO4 and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- DC UPS with LiFePo battery inside
- Operating temperature range -20…+50°C
- Power-fail Timer
- With UPScom management software
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Compact 12V DC-UPS
- Supercaps - maintenance-free
- Software UPS Control Center
- Reboot function
- DC UPS with Supercaps inside
- Maintenance free and durable
- Power-Fail timer function
- Operating temperature range -20°…+70°C
- DC UPS with LiFePo battery inside
- Powerful and reliable
- USB and RS232 Interface
- Operating temperature range -20°…+55°C
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Outdoor AC/DC UPS for extreme environments in robust aluminium housing
- IP65 protection
- Temperature range -20…+50°C
- IEC/EN 62040-1 certified
- DC UPS with 24V input and 12V output
- SuperCaps as energy storage
- Maintenance-free and fanless
- Interface RS232 & I²C
- DC/DC converter
- Fanless design for conduction cooling
- Selectable output +12V, +19V or +24VDC
- 3 years warranty
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+50°C
- DC UPS with Supercaps inside
- Operating temperature range -20...+65°C
- USB & RS232 Interface
- Incl. UPScom management software
- DC UPS with 24V input and 12V output
- 480F SuperCaps as energy storage
- Maintenance-free and fanless
- Interface RS232 & I²C
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- Compact 24V DC-UPS
- Integrated Supercaps - maintenance-free
- UPScom manegment software incl.
- Reboot function
- Flexible DC-UPS for LiFePo and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+55°C
- Flexible DC-UPS for LiFePO4 and SuperCaps
- USB and RS232 interface
- Incl. UPScom management software
- Advanced battery protection
- Fanless design for conduction cooling
- Selectable output +12V, +19V or +24VDC
- Very high efficiency up to 98%
- 3 years warranty
- DC UPS with LiFePo battery inside
- Operating temperature range -20...+55°C
- USB & RS232 Interface
- Incl. UPScom management software
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- IEC/EN and UL 62133-2 approved
- System present function
- Integrated temperature sensor
- High energy density
- Reboot function for
- DC2412-UPS(LD) - UPSIC-2403 - UPSIC-1205
- Plug-In solution
- Compact dimensions
- DC-UPS for lead acid batteries
- Zero switch over time from loss of DC input
- Operating temperature range -20°C to +60°C
- Low budget UPS solution
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium housing
- Operating temperature range -20...+50°C
- Integrated, space-saving UPS solution
- USB interface
- Reboot function
- Wall bracket available
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- IEC 62133-2 safety certification
- Outdoor DC UPS
- Protection class IP65 / IP67
- Robust aluminium enclosure
- Operating temperature range -20...+55°C
- Supercap storage for 24V DC UPS
- Maintenance-free and durable
- Extended temperature range
- LiFePO4 battery pack
- Safe, reliable and durable
- Extended temperature range
- For extended long time backups
- Compact 12V DC-UPS
- Integrated Supercaps - maintenance-free
- UPScom management software incl.
- Reboot function
- DC-UPS for lead acid batteries
- Operation temperature range from -20°C to +60°C
- Full corrosion resistant Aluminium chassis
- Low budget UPS solution