header bg
   
 


DC Emergency Power Supply

DC UPS solution for 100h long-term backup

Intelligent 24V emergency power supply with safe LiFePO4 battery technology

Protect your 24V application in case of power failure, voltage dip or flicker! Our intelligent DC UPS solution with UPSI-2406 and BP-LFP-13250S battery pack avoids system failures & data loss. The particularly safe and long-life LiFePO4 battery technology is used for the uninterruptible 24VDC power supply.





The new UPS management software 'UPScom' with cross-platform technology and intuitive user interface offers extensive functions for monitoring, parameterization and messenger services.

The powerful LiFePO4 battery pack BP-LFP-13250S with 330Wh enables backup times up to 100h, e.g. for sensor applications or emergency lighting systems. Furthermore, our DC UPS solution convinces in a variety of industries for the protection of embedded industrial PCs, controllers, drives, sensors, measurement systems, security technology and many more.


 














All features at a glance


  DC UPS solution for long-term backup up to 100h
  Powerful 24V emergency power supply
  LiFePO4 battery technology – safe & durable
  Over 6,000 charge and discharge cycles
  BMS protection and control functions
  Battery start function
  Intelligent input current detection
  USB & RS232 interface and relay contact
  UPS management software included
  Reboot function for IPC
  Extended temperature range -20...+55°C
  UN 38.3 transport certificate




Software UPScom
The completely newly developed UPS management software is now available for you to download free of charge.


Intuitive user interface and extensive functionality
The software 'UPScom' allows the connected devices to be shut down and switched off in a controlled manner during a power failure in order to avoid data loss or damage. The responsive WEB UI is called up in a web browser to set and pre-program all parameters of the DC UPS system and for real-time monitoring with state-of-charge indicator. The adjustable parameters include, among other things, load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, notifications by email.

Cross platform technology
'UPScom' uses the new WebAssembly (WASM) architecture, which runs in most current web browsers. 'UPScom' runs on x86 compatible systems and also on most ARM-64 based systems under Microsoft® Windows and various Linux distributions.






Secure Shutdown & Reboot function for IPC systems
In the event of a "power failure", the UPS signals the failure of the supply voltage via the integrated USB or RS232 interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. A script (batch) can also be executed before the system is shut down in order to process your own application-relevant processes. The integrated reboot function of the DC UPS automatically restarts the supplied IPC after the supply voltage returns, without the need for time-consuming on-site intervention by a service employee, e.g. in the case of completely self-sufficient computer systems at inaccessible locations.

Email messenger service
'UPScom' can be used for various events such as loss of connection to the UPS, system shutdown or power failure. These preventative measures can reduce or eliminate downtime.




Imprint | Privacy | Conditions