header bg
   
 


DC Emergency Power Supply

DC UPS solution for long backup times

Ensures up to 100h emergency power supply of 12VDC applications

Power failure, voltage dips or flicker? With our intelligent DC UPS solution UPSI-1208D + BP-LFP-10250S battery pack you avoid data loss & system failures. The particularly safe and durable LiFePO4 battery technology is used for the uninterruptible 12VDC power supply.






The new LiFePO4 battery pack BP-LFP-10250S (247Wh) enables long backup times up to 100h, e.g. for sensor applications or emergency lighting systems. In addition, the DC UPS solution is convincing in a variety of industries for the protection of embedded industrial PCs, controllers, drives, sensors, measuring systems, safety technology and many more.



 
















All features at a glance


  DC UPS solution for long-term backup up to 100h
  Powerful 12V emergency power supply
  LiFePO4 battery technology – safe & durable
  Over 6,000 charge and discharge cycles
  BMS protection and control functions
  Battery start function
  Intelligent input current detection
  USB & RS232 interface and relay contact
  UPS management software included
  Reboot function for IPC
  Extended temperature range -20...+55°C
  UN 38.3 transport certificate





Software UPScom
The completely newly developed UPS management software is now available for you to download free of charge.


Intuitive user interface and extensive functionality
The software 'UPScom' allows the connected devices to be shut down and switched off in a controlled manner during a power failure in order to avoid data loss or damage. The responsive WEB UI is called up in a web browser to set and pre-program all parameters of the DC UPS system and for real-time monitoring with state-of-charge indicator. The adjustable parameters include, among other things, load sensor (mA), shutdown delay, maximum backup time, minimum charge capacity before system start, notifications by email.

Cross platform technology
'UPScom' uses the new WebAssembly (WASM) architecture, which runs in most current web browsers. 'UPScom' runs on x86 compatible systems and also on most ARM-64 based systems under Microsoft® Windows and various Linux distributions.






Secure Shutdown & Reboot function for IPC systems
In the event of a "power failure", the UPS signals the failure of the supply voltage via the integrated USB or RS232 interface, so that a controlled shutdown of the computer system is initiated and valuable data is saved. A script (batch) can also be executed before the system is shut down in order to process your own application-relevant processes. The integrated reboot function of the DC UPS automatically restarts the supplied IPC after the supply voltage returns, without the need for time-consuming on-site intervention by a service employee, e.g. in the case of completely self-sufficient computer systems at inaccessible locations.

Email messenger service
'UPScom' can be used for various events such as loss of connection to the UPS, system shutdown or power failure. These preventative measures can reduce or eliminate downtime.




Imprint | Privacy | Conditions

Bicker Elektronik GmbH | Ludwig-Auer-Strasse 23 | 86609 Donauwoerth | Deutschland / Germany
Phone +49 (0)906 / 70595-0 | Fax +49 (0)906 / 70595-55 | Email: info@bicker.de

We use 100% green electricity and CO2 neutral natural gas.

Copyright © Bicker Elektronik GmbH, All rights reserved.


 
header bg