IUPS-401-B1
400 VA
- Integrated UPS
- Communication interface
- Reboot function
Other than conventional uninterruptable power supplies the IUPS-401-B1 was designed to be installed into a PC. Thus, UPS and PC become one compact space-saving unit. The IUPS-401-B1 can easily be installed into a drive slot and its handling is exceptionally user-friendly. Via interface and the UPS management software “RUPS 2000” the computer will be shut down and switched off in case of mains power failure.
| Technical data
|
|
| Output power
|
400 VA / 240 W
|
| Input voltage
|
230 V AC ±15 %
|
| Input frequency
|
50 / 60 Hz ±5 %
|
| Output voltage
|
230 V AC ±15 %
|
| Output frequency
|
50 / 60 Hz ±1 %
|
| Charging time
|
App. 8 h (90 % load)
|
| UPS Classification / Wave form
|
VFD / rectangular
|
| Protection
|
Overload protection: UPS mode: 100…120 %, alarm / 120…190 %, switch off
Mains mode: fuse
Overtemperature protection: switch off
|
| Transfer time
|
<6 ms
|
| Back up time
|
100 W / 166 VA load app. 5 minutes 180 W / 300 VA load app. 2…3 minutes
|
| Interface
|
Open collector for UPS management software
|
| Safety / EMC
|
EN62040-1-1 / CE / EN62040-2
|
| Operating temperature
|
0…+40 °C
|
| Storage temperature
|
-15…+55 °C
|
| Dimensions (WxDxH)
|
146 x 253 x 42 mm ±0.5 mm
|
| Weight (net)
|
2.75 kg
|
| Transfer limit in mains / UPS mode
|
190 V AC ±5 %
|
| Transfer limit into UPS mode in case of overvoltage at the input
|
248 V AC ±5 %
|
| Type of battery
|
2 x 6 V / 3 Ah, maintenance-free lead-gel batteries (VRLA)
|
| Noise development
|
<35 dbA
|
| Load sensor
|
Switch off at <20 Watt
|
| Button
|
To switch off alarm sound press for app. 1 second
To switch off UPS press for app. 4 seconds
To switch on UPS (cold start, without mains supply) press for app. 2 seconds
|
| Reboot function
|
If mains voltage returns after a power failure while Windows® is already shutting down, the UPS switches the PC off (after the shut-down period) and switches it on again after approximately 5 seconds in conjunction with RUPS 2000 and an ACPI-PC (observe BIOS settings of mainboard).
|
During storage the UPS has to be charged at least every 6 months.