UPSI-2402-IP-CY

24 VDC/5 A

  • Temperature range from -30…+70 °C
  • Protection class IP67
  • Robust aluminium casing

The new DC-UPS UPSI-2402-IP-CY has been designed for outdoor use. The μC-controlled DC-UPS is equipped with various protective functions and a battery control. The CYCLON cells used are characterized by a very broad operating temperature range. The CYCLON cells have a lifetime of up to 15 years which is a multiple of that of conventional lead-gel batteries. Additionally, the UPSI-2402-IP-CY is equipped with a load sensor and a timer function.

Technical data

 

Input voltage

24 V DC (22.5…30 V)

Input current

5.5 A max.

Output voltage

In normal mode: app. 0.5 V below input voltage
In battery mode: app. 29…19 VDC

Output current

5 A max.

Battery charge current

0.4 A max. (internal battery charger)

Charging method

UI characteristic, with temperature regulation

Protection

Deep discharge protection: 19 V DC ±2 %
Overload protection at output: 10 A for 2 seconds, switch off
Short-circuit protection: Switch off

Transfer time / limits

Mains / battery 20 V DC ±2 %, Battery / mains 22 V DC ±2 %

Interface

DSUB9 connector, female (at interface cable)
Outputs: Power Fail, Battery Low  Input: Shutdown
Optionally also available with UPS software for connection to common operating systems

Type of battery

Equipped CYCLON cells, maintenance-free, 12 V / 2.5 Ah

Safety / EMC

CE

Operating temperature

-30…+70 °C

Storage temperature

-40…+80 °C

Storage humidity

0…95 % RH, non-condensing

Dimensions (WxDxH)

160 x 258.5 x 85 ±0.5 mm

Weight (net)

2.7 kg

Product-specific data

Battery monitoring

Battery test is carried out in normal mode approx every 10 minutes (optional sginaling contact)

Power consumption

App. 50 mA

Shutdown suppression

During system start-up the shutdown signal is suppressed for app. 2 minutes.

Reboot function

If power fails and then returns during the shutdown mode of Windows®, the operating system will ‚lock‘ with the message „Your PC is now safe“. The reboot function restarts the system after about 10 seconds.

Load sensor

Switch-off in UPS mode <10 Watt

Timer function

2 min – 6 min – 20 min – off, adjustable via DIP switch

Back up time

App. 1h 45 min at 1 A / app. 30 min at 3 A / app. 15 min at 5 A (measured at +21 °C)