PCFD-180P-X2S
120 Watt
- +24 VDC input and UPS function
- No minimum load required
- Special voltages possible
The ATX power supply PCFD-180P-X2S with +24 VDC input uniquely combines the functions of a PC power supply with those of a UPS. Energy is provided by a separate NiMH battery pack in a practical 3.5“ format. Other output voltages can be provided upon request. A UPS software monitors the supplied system so that operation without user supervision is possible. A fit-form-compatible variation of the PCFD-180P-X2S is available with AC input as well.
| Technical data
|
|
| Input voltage
|
20…36 VDC
|
| Input current
|
6.7 A max. (24 VDC)
|
| Efficiency
|
82 % typ.
|
| Power-Good-Signal
|
Switch on delay 100…500 msec
Switch off delay 1 msec
|
| Protection
|
Short circuit protection: At each output, switch off, +5 Vsb auto-recovery, at input: fuse
Overvoltage protection: +3.3 V (3.7…4.3 V), +5 V (5.7…6.7 V), 12 V (13.8…15.6 V), +5 Vsb (5.7…7 V)
|
| Insulation voltage
|
Input / Chassis: 1000 VAC for 60 sec.
Input / Output: 1000 VAC for 60 sec.
|
| Safety / EMC
|
Designed according to EN 60950-1 and UL 60950-1
|
| Operating temperature
|
0…+60 °C
|
| Derating
|
22…20 V, 90 % load, +30…+60 °C 2 % / °C fanless, 1.3 % / °C with fan
|
| MTBF
|
100 000 h
|
| Storage temperature
|
-20…+70 °C
|
| Operating humidity
|
10…95 % RH, non-condensing
|
| Dimensions (WxDxH)
|
93 x 160 x 55 mm ±0.4 mm
|
| Weight (net)
|
0.71 kg
|
| Vibration
|
10…55 Hz with 2 G, duration 10 cycles, per x, y, z axis (out of operation)
|
| UPS function
|
By connection of battery pack BS17A-H24/2.0L
|
|
Article
No.
|
Output
voltage
|
Output current
min
|
Output current
max
|
Heat sink
max
|
Fan
max
|
Peak
5 sec.
|
Load
regulation
|
Ripple &
Noise
|
| PCFD-180P-X2S
|
+3.3 V
|
0 A
|
10 A
|
10 A
|
10 A
|
10 A
|
±5 %
|
50 mV
|
| +5 V
|
0 A
|
10 A
|
10 A
|
10 A
|
10 A
|
±5 %
|
50 mV
|
| +12 V
|
0 A
|
7.5 A
|
8.5 A
|
10 A
|
15 A
|
±5 %
|
120 mV
|
| -12 V
|
0 A
|
0.3 A
|
0.3 A
|
0.3 A
|
0.3 A
|
±10 %
|
120 mV
|
| +5 Vsb
|
0 A
|
1 A
|
1 A
|
1.5 A
|
1.8 A
|
±5 %
|
50 mV
|
Max. output power is 90 W without fan, 100 W with heat sink (>1.6 K/W) and 120 W with fan cooling (30 m3/h). Combined output load at +3.3 and +5 must not exceed 60 W in fanless operation, it must not exceed 70 W for operation with heat sink, and with fan cooling (30 m3/h) it must not exceed 83 W. Ripple and noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 47 µF ceramic capacitor at each output.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.
Technical documentation:
|