| Technical data
|
|
| Input voltage
|
-48 VDC (-36…-72 V)
|
| Input current
|
16 A max. at -48 VDC
|
| Inrush current
|
<50 A (-48 V DC / 25 °C)
|
| Efficiency
|
>80 % at full load
|
| Hold up time
|
App. 1 ms
|
| Power-Good-Signal
|
Switch on delay 100…500 ms
|
| Protection
|
Short circuit protection: Switch off with auto recovery
Inverse polarity protection input: existing
Overvoltage protection: +3.3 V (+3.6…+4.3 V), +5 V (+5.6…+6.5 V), +12 V (+13.2…+15 V), switch off
|
| Safety / EMC
|
CE, EN 60950-1, UL 60950-1
|
| Operating temperature
|
0…+70 °C, startable from -20 °C
|
| Derating
|
+40…+70 °C 1 % / °C
|
| MTBF
|
141 236 h according to MIL-HDBK-217F at +25 °C with fan
|
| Storage temperature
|
-20…+80 °C
|
| Operating humidity
|
20…85 % RH, non-condensing
|
| Dimensions (WxDxH)
|
150 x 140 x 86 mm ±0.5 mm
|
| Weight (net)
|
1.65 kg
|