| Technical data
|
|
| Input voltage
|
90…264 VAC (active PFC), 127…380 VDC
|
| Input frequency
|
47…63 Hz
|
| Input current
|
4 A (115 VAC) / 2 A (230 VAC)
|
| Inrush current
|
30 A (115 VAC) / 60 A (230 VAC)
|
| Efficiency
|
≥75 % (at rated load and 115 VAC)
|
| Hold up time
|
>16 ms (at rated load and 115 VAC)
|
| Power-Good-Signal
|
Switch on delay 100…500 ms
Switch off delay 1 ms
|
| Protection
|
Short circuit protection: At each output, switch off (-12 V shutdown of 3PIN regulator)
Overload protection: 130…160 %, switch off
Overvoltage protection: +5 V (+5.4…+5.8 V), switch off
Overtemperature protection: switch off at +110 °C (temperature of primary heatsink)
|
| Earth leakage current
|
<3.5 mA
|
| Safety / EMC
|
CE, UL 60950-1, CB: IEC 60950-1
|
| Operating temperature
|
0…+70 °C
|
| Derating
|
2.5 % / °C from +50…+70 °C
|
| MTBF
|
181 000 h at +25 °C according to MIL-217F
|
| Storage temperature
|
-20…+70 °C
|
| Operating humidity
|
5…95 % RH, non-condensing
|
| Dimensions (W x D x H)
|
97 x 198 x 40 mm ±0.4 mm
|
| Weight (net)
|
0.7 kg
|