BEA-640-B5

400 Watt

  • Improved vibration protection according to EN 60945
  • Conductor plate with coating
  • Safety clip for power cord

The power supply BEA-640-B5 has been optimized for use in maritime navigation and radio communication devices according to EN 60945:2002. The robust power supply is designed for uninterrupted operation (24/7) and is built using only high quality components. The power cord is secured by means of a safety clip. Fan monitoring is ensured via a reliable tachometric signal.

Technical data

 

Input voltage

90…264 VAC, 120…380 VDC, active PFC

Input frequency

47…63 Hz

Input current

7 A (115 VAC) / 3.5 A (230 VAC)

Inrush current

49 A (115 VAC) / 94 A (264 VAC)

Efficiency

≥75 %, 230 VAC / ≥70 %, 115 VAC (full load)

Hold up time

>16 ms

Power-Good-Signal

Switch on delay 100…500 ms
Switch off delay 1 ms

Protection

Short circuit protection: At every output, switch off / +5 Vsb, auto-recovery
Overload protection: 110…150 %, switch off
Overvoltage protection: +3.3 V (+3.9…+4.3 V), +5 V (+5.7…+6.5 V), +12 V (+13.6…+15 V)

Insulation voltage

Input / Chassis 3100 VDC
Input / Output 4242 VDC

Earth leakage current

<3.5 mA, 115 VAC / 230 VAC

Operating temperature

-10…+70 °C

Derating

+50…+70 °C, 1 % / °C

MTBF

100 000 h at 50 °C, without fan

Storage temperature

-20…+80 °C

Operating humidity

10…90 % RH, non-condensing

Dimensions (WxDxH)

150 x 140 x 86 mm ±0.5 mm

Weight (net)

2.1 kg

Article
No.

Output
voltage

Output current
min

Output current
max

Load
regulation

Ripple &
Noise

BEA-640-B5

+3.3 V

0 A

28 A

±5 %

50 mV

+5 V

0.5 A

35 A

±5 %

50 mV

+12 V

1 A

30 A

+7/-5 %

120 mV

-12 V

0 A

0.8 A

±5 %

150 mV

-5 V

0 A

0.5 A

±5 %

150 mV

+5 Vsb

0 A

2 A

±5 %

50 mV

Max. output is 400 W, combined max. output current at +3.3 V and +5 V must not exceed 45 A. Ripple and Noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 220 µF electrolytic capacitor and 0.1 µF ceramic capacitor at each output. During a cross regulation test we recommend to keep the channel with higher output load at 80 % of its max. power and the channel with lower output load at 20 % of its max. power.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.

Technical documentation:
© 2008-2012  |  BICKER ELEKTRONIK GmbH - Ludwig-Auer-Straße 23 - 86609 Donauwörth (DE)
Phone +49 (0)906 / 70595-0 - Fax +49 (0)906 / 70595-55