DD6
6 Watt
- Operating temperature -20…+60 °C
- Input / Output galvanically isolated
- Widerange inputn
The DD6 series is designed for mounting rail assembly. Screw terminals enable universal application in mechanical engineering. By a widerange input of 9…36 VDC the converters can be deployed under the most various conditions. The individual models provide different output voltages.
| Technical data |
|
|---|---|
| Input voltage |
9…36 VDC |
| Input current |
0.8 A max (9 VDC), 0.28 A max. (24 VDC) |
| Efficiency |
App. 78 % |
| Protection |
Short circuit protection: yes, auto-recovery |
| Insulation voltage |
1500 VDC Input / Output |
| Cooling |
Convection |
| Temperature coefficient |
0.05 % / °C |
| Operating temperature |
-20…+60 °C |
| Storage temperature |
-40…+85 °C |
| Operating humidity |
10…90 % RH, non-condensing |
| Dimensions (WxDxH) |
61 x 21 x 62 mm ±0.8 mm |
| Weight (net) |
0.05 kg |
| Product-specific data |
|---|
| Voltage regulation |
±2 % |
| Line regulation |
±1 % |
| Load regulation |
±1 % |
|
Article |
Output |
Output current |
Output current |
Ripple & |
|---|---|---|---|---|
| DD6-5 |
+5 V |
0 A |
1 A |
100 mV |
| DD6-10 |
+10 V |
0 A |
0.5 A |
100 mV |
| DD6-12 |
+12 V |
0 A |
0.47 A |
120 mV |
| DD6-24 |
+24 V |
0 A |
0.23 A |
240 mV |
Ripple and noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 10 nF capacitor and 1 µF capacitor at each output.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.