UPSI-1202

12 VDC/6 A

  • Continuous battery monitoring
  • Timer function
  • PC interface

The newly designed DC UPS UPSI-1202 protects connected consumer loads from supply voltage fluctuations and interruptions. The μC controlled DC UPS provides various protections. Among the most important is the continuous battery monitoring feature. This ensures that sufficient capacitance remains in the battery to guarantee the supply of consumer loads in case of power failure. New features of the UPSI-2401 are a load sensor and a timer function. The timer function was integrated and allows a timer-controlled switch-off of the UPS.

Technical data

 

Input voltage

12 VDC (10.6…16 V)

Input current

6.6 A max.

Output voltage

In normal mode: app. 0.65 V max. below input voltage
In battery mode: app. 12.6…9.7 VDC

Output current

6 A max.

Battery charge current

0.6 A max. (interneral battery charger)

Charging method

UI characteristic, with temperature regulation

Protection

Deep discharge protection: 9.7 VDC ±2 %
Overload protection at output: 7.7 A for 2 seconds, switch off
Short circuit protection: Switch off

Transfer time / limits

Mains / Battery 9.7 VDC ±2 %, Battery / Mains 10.6 VDC ±2 %
Battery ok / Battery low 10.8 VDC, Battery low / Battery ok 11.2 VDC

Interface

DSUB9 connector, female Outputs: Power Fail, Battery Low / Input: Shutdown
Optionally also available with UPS software for connection to common operating systems

Type of battery

Lead-gel-battery, maintenance-free, 2x 6 V / 3.0 Ah (recommended)

Safety / EMC

CE

Operating temperature

-20…+60 °C

Storage temperature

-40…+80 °C

Storage humidity

0…95 % RH, non-condensing

Dimensions

100 x 120 x 24.7 mm ±0.5 mm

Weight (net)

0.25 kg

Product-specific data

LED display

3-colour-LED for „Power ok” (green), „Power Fail” (orange), „Battery low” (red/orange flashing) and „Battery defect” (red/green flashing), short circuit at aoutput (red)

Battery monitoring

Battery test is carried out in normal mode approx every 10 minutes, in case of “Battery defect“ notification the LED flashes red/green (optional sginaling contact)

Power consumption

App. 100 mA

Shutdown

During system start-up the shutdown signal is suppressed for app. 2 minutes

Reboot function

If power fails and then returns during the shutdown mode of Windows®, the operating system will ‚lock‘ with the message „Your PC is now safe“. The reboot function restarts the system after about 5 seconds.

Load sensor

Switch off in UPS mode <10 Watt

Timer function

2 min – 6 min – 20 min – off, adjustable via DIP switch

Back up time

App. 60 min. at 1.7 A, app. 25 min. at 3 A, app. 8 min. at 6 A (measured at +20 °C)

Optional accessories

Article-No.

Designation

RUPS 2000-B1 UPS Management Software (CD-ROM) link to the product
CB-RS-020 Interface cable, 9-pole link to the product
LC-R063R4PG Maintenance-free lead battery, 6 A/3.4 Ah (2 peaces needed) link to the product
BP-0625 CYCLON battery pack, 6 V/2.5 Ah, -30…+70 °C (2 peaces needed) link to the product
Technical documentation: