You are here: Bicker Elektronik / Products / Industrial PC PSUs / AC input / P1S-6300V

P1S-6300V

300 Watt

  • Efficiency up to 83 %
  • Silent due to fan regulation
  • TÜV approval up to +50 °C

Thanks to its high efficiency and a temperature-regulated fan the noise produced by the P1S-6300V is minimal. Its robust construction ensures a long service-life under industrial operating conditions. All equipped components are of high-grade quality and designed for an ambient temperature of +50 °C. The regulation properties of the P1S-6300V are very good. Upon request the P1S-6300V is also available with a special cable harness.

Technical data

 

Input voltage

90…264 VAC, active PFC

Input frequency

47…63 Hz

Input current

4.5 A (115 V) / 2 A (230 V)

Inrush current

70 A (115 VAC) / 140 A (230 VAC)

Efficiency

≥80…83 %, 230 VAC

Hold up time

>16 msec

Power-Good-Signal

Switch on delay 100…500 msec
Switch off delay 1 msec

Protection

Short circuit protection: +3.3 V, +5 V, +12 V, switch off / -12 V, +5 Vsb, auto recovery
Overload protection: 110…160 %, switch off
Overvoltage protection: +3.3 V (+3.6…+4.3 V), +5 V (+5.6…+6.5 V), +12 V (+13.2…+15 V)

Earth leakage current

<3,5 mA, 115 VAC/230 VAC

Safety / EMC

TÜV, UL, CE

Operating temperature

0…+50 °C

MTBF

140 000 h at +25 °C, with fan

Storage temperature

-20…+80 °C

Operating humidity

20…80 % RH, non-condensing

Dimensions (W x D x H)

150 x 81.5 x 40.3 mm, ±0.5 mm

Weight (net)

1.3 kg

Article
No.

Output
voltage

Output current
min

Output current
max

Load
regulation

Ripple &
Noise

P1S-6300V

+3.3 V

0.5 A

17 A

±5 %

60 mV

+5 V

1 A

18 A

±5 %

60 mV

+12 V1

0 A

8 A

±5 %

120 mV

+12 V2

2 A

16A

±5 %

120 mV

-12 V

0 A

0.3 A

±10 %

120 mV

+5 Vsb

0.1 A

2.5 A

±5 %

60 mV

Max. output power is 300 W, combined at +3.3 V and +5 V 120 W. Ripple and noise was measured by a 20 MHz oscilloscope with connected 100 μF electrolytic capacitor and 0.1 μF ceramic capacitor at each output.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.

Technical documentation: