You are here: Bicker Elektronik / Products / Industrial PC PSUs / AC input / MRT-6300P-2AC-B2

MRT-6300P-2AC-B2

300 Watt

  • Silent due to regulated fan
  • Real redundancy
  • 2 mains connectors

The mini-redundant MRT-6300P-2AC-B2 is designed as PS/2 substitute and for 19“ rack servers as well as storage systems. If one plug-in power supply fails, the second unit takes over the full load without any interruption. Since the defect plug-in unit can be replaced during operation a very high availability of the system is guaranteed. Due to the separate mains connectors supply is possible from different networks as well (UPS).

Technical data

 

Input voltage

90…264 VAC, active PFC

Input frequency

47…63 Hz

Input current

6 A / (115 VAC) / 3 A (230 VAC)

Inrush current

60 A (115 VAC) / 80 A (230 VAC)

Efficiency

>64 %

Hold up time

16 ms

Power-Good-Signal

Switch on delay 100…500 ms

Protection

Short circuit protection: At each output
Overvoltage protection: +3.3 V (+3.9…+5 V) / +5 V (+5.7…+6.5 V) / +12 V (+13…+15 V)
Overload protection: 110…160 %

Earth leakage current

<3.5 mA

Safety / EMC

TÜV / UL / cUL / CB / CE

Operating temperature

0…+45 °C

MTBF

100 000 h at 25 °C, calculated without fan

Storage temperature

-20…+80 °C

Operating humidity

20…90 % RH, non-condensing

Dimensions (WxDxH)

150 x 185 x 86 mm ±0.5 mm

Weight (net)

3.4 kg

Product-specific data

Alarm functions

1. Reset for acoustic alarm, 2. Failure LED, 3. TTL signal

Article
No.

Output
voltage

Output current
min

Output current
max

Load
regulation

Ripple &
Noise

MRT-6300P-2AC-B2

+3.3 V

1 A

18 A

±5 %

±50 mV

+5 V

3 A

25 A

±5 %

±50 mV

+12 V

2 A

16 A

±7 %

±120 mV

-12 V

0 A

0.5 A

±10%

±150 mV

-5 V

0 A

0.5 A

±10 %

±100 mV

+5 Vsb

0.1 A

2 A

±5 %

±60 mV

Combined output load at +3.3 V, +5 V and +12 V must not exceed 282 W. Combined output current at +3.3 V and +5 V must not exceed 35 A. Ripple and Noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 220 µF tantalum capacitor and 0.1 µF ceramic capacitor at each output.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.