OZP-170 series

210 Watt

  • 168 Watt continuous fanless power
  • Exceptionally rugged and long-lasting
  • High efficiency up to 86 %

OZP-170 single voltage power supplies stand out through their high peak performance. Thus they are ideal for e.g. high-performance thermo transfer printers. Output voltage for the OZP-170-12/15 is selectable as required between 12 V and 15 V. In the „-JB0“ version the OZP-170-24 is also available with a backup function. In case of a power failure the output is supplied via the NiMH battery pack.

Technical data

 

Input voltage

85…264 VAC, active PFC

Input frequency

47…63 Hz

Input current

Max. 2.6 A / 100 VAC, max. 1.4 A / 200 VAC

Inrush current

<17 A / 100 VAC, <34 A / 200 VAC, +25 °C

Efficiency

82…86 %

Hold up time

App. 20 ms

Protection

Short circuit protection: Switch off with auto-recovery
Overload protection: Switch off with auto-recovery
Overvoltage protection: Switch off (model / response threshold)
OZP-170-12 /15 (13.8…16.2 V), OZP-170-12/15  (17.3…20.3 V), OZP-170-24 (30…35 V)

Line regulation

<94 mV

Load regulation

<150 mV

Earth leakage current

<0.5 mA / 200 VAC

Safety / EMC

TÜV, UL, CE

Operating temperature

-10…+70 °C

Derating

Depending on mounting position and temperature (see diagrams in data sheet)
Input voltage 95…85 VAC, 1 % / VAC

MTBF

>268 000 h according to EI AJRCR-9102

Storage temperature

-20…+75 °C

Operating humidity

20…90 % RH, non-condensing

Dimensions

73 x 40 x 222 mm ±0.5mm
83 x 51 x 252 mm (with cover), optional

Weight (net)

0.5 kg, 0.8 kg with cover

Product-specific data

OZP-170-12/15

Change-over via jumper CN9 (12 V CN9 plugged, 15 V CN9 open)

Adjustment range

OZP-170-12 /15: ±10 %, OZP-170-12/15 : -5 % / +10 %, OZP-170-24: -5 % / +20 %

Backup function

OZP-170-24 with battery packs BS14A-H24/2.5L

Article
No.

Output
voltage

Output
current
min

Output
 current
 rated load

Output
 current
 fanless

Output
 current
 peak

Ripple &
Noise

Efficiency

OZP-170-12 /15

+12 V

0 A

14 A

17.5 A

22.5 A

<180 mVss

85 %

OZP-170-12/15

+15 V

0 A

11.2 A

14 A

18 A

<180 mVss

85 %

OZP-170-24

+24 V

0 A

7 A

14 A

8.8 A / 12.5 A

<180 mVss

85 %

Max. continuous power is 168 W (convection), 210 W (fan cooling), 270 W (Peak OZP-170-12/15) and 300 W (Peak OZP-170-24). Peak load can be for 10 sec. Ripple and noise was measured by a 100 MHz-oscilloscope with connected 10 μF electrolytic capacitor and 100 nF ceramic capacitor at each output.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.