You are here: Bicker Elektronik / Products / Industrial PC PSUs / UPS function / PCFL-180P-X2S2

PCFL-180P-X2S2

150 Watt

  • UPS function with NiMH battery pack
  • No minimum load required
  • Special voltages possible

The ATX power supply PCFL-180P-X2S2 uniquely combines the functions of a PC power supply with those of a UPS. Energy is provided by a separate NiMH battery pack in a practical 3.5“ format. Upon request it is also available with additional 24 V DC output voltage. A UPS software monitors the supplied system so that operation without user supervision is possible. A fit-form-compatible variation of the PCFL-180P-X2S2 is available with DC input as well.

Technical data

 

Input voltage

85…264 VAC, active PFC

Input frequency

47…63 Hz

Input current

2 A (100 VAC) / 0.9 A (220 VAC)

Efficiency

77 % typ.

Hold up time

16 msec (without battery pack)

Power-Good-Signal

Switch on delay 100…500 msec
Switch off delay 1 msec

Protection

Short circuit protection: At each output, switch off, +5 Vsb auto-recovery, at input: fuse
Overvoltage protection: +3.3 V (3.7…4.3 V), +5 V (5.7…6.7 V), 12 V (13.8…15.6 V), +5 Vsb (5.7…7 V)

Insulation voltage

Input / Chassis: 1500 VAC for 60 sec.
Input / Output: 1500 VAC for 60 sec.

Safety / EMC

CE, EN 60950-1, UL 60950-1

Operating temperature

0…+60 °C

Derating

85…90 V, 80 % load +30…+60 °C 2% / °C fanless, 1.3 % / °C with fan

MTBF

100 000 h

Storage temperature

-20…+70 °C

Operating humidity

10…95 % RH, non-condensing

Dimensions (WxDxH)

93 x 160 x 55 mm ±0.4 mm

Weight (net)

0.85 kg

Product-specific data

Vibration

10…55 Hz with 2 G, duration 10 cycles, per x, y, z axis (out of operation)

UPS function

By connection of battery pack BS17A-H24/2.0L

Article
No.

Output
voltage

Output current
min

Output current
 max

Heat sink
max

Fan
max

Peak
5 sec.

Load
regulation

Ripple &
Noise

PCFL-180P-X2S2

+3.3 V

0 A

10 A

10 A

10 A

10 A

±5 %

50 mV

+5 V

0 A

10 A

10 A

10 A

10 A

±5 %

50 mV

+12 V

0 A

7.5 A

8.5 A

10 A

15 A

±5 %

120 mV

-12 V

0 A

0.3 A

0.3 A

0.3 A

0.3 A

±10 %

120 mV

+5 Vsb

0 A

1 A

1 A

1.5 A

1.8 A

±5 %

50 mV

Max. output power is 90 W without fan, 100 W with heat sink (>1.6 K/W) and 150 W with fan cooling (30 m3/h). Combined output load at +3.3 and +5 V must not exceed 60 W in fanless operation, it must not exceed 70 W for operation with heat sink, and with fan cooling (30 m3/h) it must not exceed 83 W. Ripple and noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 47 µF ceramic capacitor at each output.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.

Optional accessories

Article-No.

Designation

BS17A/H24/2.0L NiMH battery pack, 24 V/2,0 Ah link to the product
RUPS 2000-B1 UPS Management Software (CD-ROM) link to the product
WH-M2022-500-01 PCFD/L-180P / 20 pin ATX connector / 500 mm link to the product
WH-PS610-850 3x HD / 2x SATA / 1x FDD cable harness / 850 mm link to the product
CB-PCFL AC input cable for PCFL-180P link to the product