BES-630V
320 Watt
- +12 VDC input
- Temperature controlled ball-bearing fan
- Temperature range 0…+60 °C
The DC PC power supply BES-630V provides a +12 V DC input to supply computer systems for industrial applications or in mobile systems. Due to its wide input voltage range from 9 to 18 V DC the BES-630V remains unaffected by input voltage fluctuations. Its ambient operating temperature ranges from 0 °C to +60 °C.
| Technical data |
|
|---|---|
| Input voltage |
+12 VDC (9…18 V) |
| Input current |
47 A max. at 12 VDC |
| Efficiency |
Approx. 70 % at half load (12 VDC) |
| Power-Good-Signal |
100…500 msec |
| Protection |
Short circuit protection: Switch off with auto-recovery |
| Safety / EMC |
Designed according to EN 60950, UL 60950 |
| Operating temperature |
0…+60 °C |
| Storage temperature |
-20…+80 °C |
| Operating humidity |
20…85 % RH, non-condensing |
| Dimensions (W x D x H) |
150 x 140 x 86 mm ±0.5 mm |
| Weight (net) |
2.3 kg |
| Product-specific data |
|---|
| Max. operating heigth |
10 000 feet above sea level |
|
Article |
Output |
Output current |
Output current |
Load |
Mains |
Cross |
Ripple & |
|---|---|---|---|---|---|---|---|
| BES-630V |
+3.3 V |
0 A |
15 A |
±5 % |
±1 % |
±5 % |
±50 mV |
| +5 V |
2 A |
30 A |
±5 % |
±1 % |
±5 % |
±50 mV |
|
| +12 V |
1 A |
15 A |
±5 % |
±1 % |
±5 % |
±120 mV |
|
| -12 V |
0 A |
1 A |
±8 % |
±1 % |
±5 % |
±120 mV |
|
| -5 V |
0 A |
1 A |
±5 % |
±1 % |
±5 % |
±50 mV |
|
| +5 Vsb |
0 A |
2 A |
±5 % |
±1 % |
±5 % |
±50 mV |
Max. output power is 320 W, combined at +3.3 V and +5 V it is 150 W. Ripple and noise was measured by a 20 MHz-oscilloscope with connected 10 µF electrolytic capacitor and 0.1 µF ceramic capacitor at each output. During a cross regulation test we recommend to keep the channel with higher output load at 80 % of its max. power and the channel with lower output load at 20 % of its max. power. From 5 V / >20 A onwards a load of >6 A must be connected at +12.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.