You are here: Bicker Elektronik / Products / Industrial PC PSUs / DC input / BES-630C

BES-630C

300 Watt

  • +24 VDC input
  • Operating temperature -20…+70 °C
  • UL508 certified

The 300 W DC PC power supply BES-630C provides a +24 V DC input for powering computer systems applied in automation or mobile systems. It is designed for an operating ambient temperature range of -20 up to +70 °C. Due to its widerange input from 18 to 32 V DC the BES-630C remains unaffected by input voltage fluctuations. Thanks to the softstart function the BES-630C does require no higher inrush current as compared to normal operation.

Technical data

 

Input voltage

+24 VDC (18…32 V)

Input current

21 A max. at 18 VDC

Inrush current

5 A

Efficiency

>65 %

Hold up time

App. 7 ms at +24 VDC and 290 W

Power-Good-Signal

Switch on delay 100…500 ms

Protection

Short circuit protection: Switch off with auto-recovery
Overload protection: Switch off with auto-recovery
Overvoltage protection: +5 V (+5.7…+7 V)

Insulation voltage

Input / Chassis 1414 VDC
Input / Output 2828 VDC

Safety / EMC

UL60950, UL508, CAN / CSA C22.2 No. 14-M 95, CE

Operating temperature

-20…+70 °C

Derating

300 W at 30 °C / 210 W at 50 °C / 150 W at 70 °C
300 W at input voltage 24…32 V, 250 W at input voltage 18…23 V

MTBF

>116 000 h at +50 °C according to MIL-HDBK-217F

Storage temperature

-40…+75 °C

Operating humidity

5…95 % RH, non-condensing, at +40 °C

Dimensions

150 x 140 x 86 mm ±0.5 mm

Weight (net)

1.65 kg

Article
No.

Output
voltage

Output current
min

Output current
 max

Output current
 rated load

Load
regulation

Voltage
regulation

Ripple &
Noise

BES-630C

+3.3 V

0 A

15 A

8 A

±2 %

±5 %

±50 mV

+5 V

2 A

30 A

25 A

±3 %

±5 %

±50 mV

+12 V

0.1 A

15 A

10 A

±5 %

±5 %

±100 mV

-12 V

0 A

2 A

1 A

±2 %

±5 %

±100 mV

-5 V

0 A

2 A

1 A

±2 %

±5 %

±100 mV

+5 Vsb

0 A

1.2 A

0.72 A

±3 %

±5 %

±100 mV

Combined output power at +3.3 V and +5 V must not exceed 150 W. The +12 V output can supply up to 15 A if + 5 V / 15 A is connected. From a load of 100 W (+3.3 V and +5 V) onwards a minimum load of 1.2 A must be connected at +12 V. Load regulation and voltage regulation were done by changing the measured output load ±40 % from 60 % rated load and all other outputs kept at 60 % rated load. Ripple and Noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 0.47 µF ceramic capacitor at each output.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.