400 Watt

  • Temperature-controlled fan
  • Passive backplane
  • 2 mains voltage inputs

The energy-saving properties of the redundant server PSU M1Z2-5400V3V-B2 are achieved by its very high efficiency and low dissipation loss. It is distinguished by its innovative circuit design focusing on low current consumption. The completely redundant power supplies can be replaced during operation and so they ensure a very long availability of the system. Separate mains connectors allow supply from different power sources (UPS). Models with 460, 500 or 550 W power are also available.

Technical data

 

Input voltage

90…264 VAC

Input frequency

47…63 Hz

Input current

6 A / (115 VAC) / 3 A (230 VAC)

Inrush current

35 A (115 VAC) / 40 A (230 VAC)

Efficiency

>78 % / 115 VAC

Hold up time

16 ms

Power-Good-Signal

Switch on delay 100…500 ms

Protection

Short circuit protection: At every output
Overvoltage protection: +3.3 V (+3.4…+5.7 V) / +5 V (+5.7…+6.5 V) / +12 V (+14.3…+17.3 V)
Overload protection: 110…160 % each module

Earth leakage current

<3,5 mA at 250 VAC

Safety / EMC

TÜV / CB / CE

Operating temperature

0…+50 °C

Storage temperatur

-20…+80 °C

Operating humidity

20…80 % non-condensing

Dimensions (WxDxH)

101 x 265 x 84 mm ±0.5 mm

Weight (net)

6 kg

Product-specific data

Alarm functions

1. TTL signal, 2. Failure LED, 3. Reset for acoustic alarm

Article
No.

Output
voltage

Output current
min

Output current
 max

Load
regulation

Ripple &
Noise

M1Z2-5400V3V-B2

+3.3 V

0 A

24 A

±5 %

±70 mV

+5 V

0.5 A

24 A

±5 %

±70 mV

+12 V

1 A

32 A

±6 %

±120 mV

-12 V

0 A

0.8 A

±10 %

±120 mV

+5 Vsb

0 A

3.5 A

±5 %

±70 mV

Combined output power at +3.3 V, +5 V, and +12 V must not exceed 450 W. Ripple and Noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 220 µF electrolytic capacitor and 0.1 µF ceramic capacitor at each output. During a cross regulation test we recommend to keep the channel with higher output load at 80 % of its max. power and the channel with lower output load at 20 % of its max. power.
This power supply is for assembly purposes only and it must not be operated in unassembled condition. The final assembly has to comply with the valid EMC standards.