BEP-515
150 Watt
- 150 Watt continuous fanless power!
- Operating temperature 0…+70 °C
- For 1 U systems
By its rugged design the 150 W ATX power supply BEP-515 is the ideal power supply for fanless working applications. Full power can be supplied without cooling at an ambient temperature of +50 °C. For easy connection an ATX cable harness is available. Fit-form-function compatible power supplies with DC input or for medical use are available as BEP-515C and BEP-515M, respectively.
| Technical data |
|
|---|---|
| Input voltage |
90…264 VAC (active PFC), 127…380 VDC |
| Input frequency |
47…63 Hz |
| Input current |
4 A (115 VAC) / 2 A (230 VAC) |
| Inrush current |
30 A (115 VAC) / 60 A (230 VAC) |
| Efficiency |
≥75 % (at rated load and 115 VAC) |
| Hold up time |
>16 ms (at rated load and 115 VAC) |
| Power-Good-Signal |
Switch on delay 100…500 ms |
| Protection |
Short circuit protection: At each output, switch off (-12 V shutdown of 3PIN regulator) |
| Earth leakage current |
<3.5 mA |
| Safety / EMC |
CE, UL 60950-1, CB: IEC 60950-1 |
| Operating temperature |
0…+70 °C |
| Derating |
2.5 % / °C from +50…+70 °C |
| MTBF |
181 000 h at +25 °C according to MIL-217F |
| Storage temperature |
-20…+70 °C |
| Operating humidity |
5…95 % RH, non-condensing |
| Dimensions (W x D x H) |
97 x 198 x 40 mm ±0.4 mm |
| Weight (net) |
0.7 kg |
| Product-specific data |
|---|
| Startup delay |
0.3…6 sec (230 VAC…115 VAC) |
|
Article |
Output |
Output current |
Output current |
Output current |
Load |
Line |
Ripple & |
|---|---|---|---|---|---|---|---|
| BEP-515 |
+3.3 V |
0.5 A |
12 A |
7.5 A |
±4 % |
±1 % |
50 mV |
| +5 V |
1 A |
14 A |
11 A |
±2 % |
50 mV |
||
| +12 V |
0 A |
10 A |
5 A |
±4 % |
100 mV |
||
| -12 V |
0 A |
1.0 A |
0.5 A |
±5 % |
150 mV |
||
| +5 Vsb |
0 A |
1.5 A |
0.75 A |
±4 % |
100 mV |
Combined output load at +3.3 V and +5 V must not exceed 90 W. The +5 V output can supply up to 14 A if a minimum load of +3.3 V / 1.3 A and +12 V / 3 A is connected. The +3.3 V output can supply 12 A if a minimum load of +5 V / 3 A and +12 V / 0.2 A is connected. Ripple and Noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 10 µF electrolytic capacitor and 0.1 µF ceramic capacitor at each output. Load regulation was done by changing the measured output load ±40 % from 60 % rated load and all other outputs kept at 60 % rated load.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.
| Optional accessories | ||
Article-No. |
Designation |
|
|---|---|---|
| CB-515 | ATX cable harness for BEP-515 | link to the product |