You are here: Bicker Elektronik / Products / Industrial PC PSUs / AC input / BEA-740

BEA-740

450 Watt

  • Additional +24 VDC output
  • High-quality electrolyte capacitors (+105 °C)
  • Designed for continuous operation 24/7

The BEA-740 power supply for industrial applications is equipped with an additional +24 VDC output. Peripheral equipment such as printers, magnetic card readers, scanners, etc. can be directly supplied with this PSU. Due to its high power rating of 120 W an additional 24 VDC power supply is usually no longer required. Typical fields of application are automatic cash dispensers, monitoring equipment, Point-of-Sale (POS) and Point-of-Information (POI) applications.

Technical data

 

Input voltage

90…264 VAC, 120…380 VDC, active PFC

Input frequency

47…63 Hz

Input current

8 A (115 VAC) / 4 A (230 VAC)

Inrush current

40 A (115 VAC) / 60 A (230 VAC)

Efficiency

≥70 %, 115 VAC (full load)

Hold up time

>16 ms

Power-Good-Signal

Switch-on delay 100…500 ms
Switch-off delay 1 ms

Protection

Short circuit protection: At each output, switch off / +5 Vsb, auto-recovery
Overload protection: 110…150 %, switch off
Overvoltage protection: +3.3 V (+3.9…+4.3 V), +5 V (+5.7…+6.5 V), +12 V (+13.6…+15 V)

Insulation voltage

Input / Chassis 3100 VDC
Input / Output 4242 VDC

Earth leakage current

<3.5 mA, 115 VAC/230 VAC

Safety / EMC

CE

Operating temperature

0…+50 °C

Storage temperature

-20…+80 °C

Operating humidity

10…90 % RH, non-condensing

Dimensions (W x D x H)

150 x 140 x 86 mm ±0.5 mm

Weight (net)

2.1 kg

Article
No.

Output
voltage

Output current
min

Output current
 max

Load
regulation

Ripple &
Noise

BEA-740

+3.3 V

0.5 A

21 A

±5 %

50 mV

+5 V

1 A

25 A

±5 %

50 mV

+12 V

0.5 A

24 A

±5 %

120 mV

-12 V

0 A

0.5 A

±5 %

120 mV

-5 V

0 A

0.5 A

±5 %

120 mV

+5 Vsb

0 A

2 A

±5 %

50 mV

+24 V

0 A

5 A

±5 %

200 mV

Ripple and noise was measured by a 20 MHz bandwidth limited oscilloscope with connected 220 µF electrolytic capacitor and 0.1 µF ceramic capacitor at each output. During a cross regulation test we recommend to keep the channel with higher output load at 80 % of its max. power and the channel with lower output load at 20 % of its max. power. From +5 V / ≥15 A onwards a load of ≥1 A must be connected at +12 V.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.