BES-307VC

70 Watt

  • 10…30 V input range
  • 50 Watt continuous fanless power
  • Operating temperature 0…+50 °C

The DC/DC converter BES-307VC was developed for industrial and mobile computer systems with low power requirements. Due to its input voltage range of 10…30 VDC it can be univer-sally applied, for 24 VDC industrial networks and in the automotive branch. The possible fields of application for the BES-307VC are enlarged further by its compact design and fanless operation.

Technical data

 

Input voltage

10…30 VDC

Input current

13 A (10 VDC)

Inrush current

25 A (12 VDC)

Efficiency

>70 % (24 V) / >65 % (12 V), at nominal load

Protection

Short circuit protection: At each output, auto-recovery
Overload protection: 110…150 %
Overvoltage protection: +5 V (5.7…7 V)
Overcurrent protection: 5 VDC / 20 A max.
Inverse-polarity protection: diode at input

Insulation voltage

Input / Ground 1000 VDC for 1 sec.
Input / Output 2800 VDC for 60 sec.

Cooling

Output power is 50 W without fan, 70 W with 42CFM (67 m3 / h) fan.
Peak current for +24 V input (+25 °C) can be for 10 sec at +5 V / 14 A or at +12 V / 3 A

Operating temperature

0…+50 °C

MTBF

262 000 h at +50 °C according to MIL-HDBK-217F

Storage temperature

-20…+85 °C

Operating humidity

10 % to 90 % RH, non-condensing

Dimensions

127 x 76.2 x 41 mm ±0.8 mm

Weight (net)

0.33 kg

Articel
No.

Output
voltage

Output current
min

Output current
 max

Load
regulation

Line
regulation

Ripple &
Noise

BES-307VC

+5 V

0 A

10 A

±3 % (load step ±40 % related to 60 % load)

±2 % (at rated
load and input
voltage change
of ±10 % at
+12 V or +24 V)

50 mV

+12 V*

0 A

1.5 A

±5 % (load step ±40 % related to 60 % load)

100 mV

-12 V*

0 A

0.3 A

+8/-3 % (load step ±40 % related to 60 % load)

100 mV

With max. load at +5 V / 10 A and +12 V / 1.5 A a minimum load of -12 V / 0.1 A must be connected. With max. load at +5 V / 10 A a minimum load of +12 V / >0.2 A and -12 V / 0.03 A must be connected.
* When the minimum load requirements are not observed, the input voltages can rise and damage the connected consumer loads.
Ripple and noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 0.47 µF ceramic capacitor at each output. For connection to a low voltage mains supply an additional input filter may be required.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.

Technical documentation: