BES-307CT
70 Watt
- 18…56 VDC input range
- Operating temperature 0…+50 °C
- Installation height only 38 mm
The widerange input voltage of 18…56 VDC provided by the DC/DC converter BES-307CT includes the typical voltages 24 V, 28 V, 36 V and 48 V. It was especially developed for industrial and mobile computer systems with low power requirements. The possible fields of application for the BES-307CT are enlarged further by its compact design and fanless operation.
| Technical data |
|
|---|---|
| Input voltage |
18…56 VDC |
| Input current |
4 A (+48 V) |
| Inrush current |
<15 A at +25 °C |
| Efficiency |
>70 % at rated load |
| Protection |
Short circuit protection: At each output, auto-recovery |
| Insulation voltage |
Input / Chassis 1000 VAC |
| Operating temperature |
0…+50 °C |
| MTBF |
247 000 h according to MIL-HDBK-217F at +50 °C |
| Storage temperature |
-20…+70 °C |
| Operating humidity |
10…90 % RH, non-condensing |
| Dimensions |
134 x 84 x 38 mm ±0.8 mm |
| Weight (net) |
0.4 kg |
|
Article |
Output |
Output current |
Output current |
Load |
Line |
Ripple & |
|---|---|---|---|---|---|---|
| BES-307CT |
+5 V |
1 A |
12 A |
±1 % |
±1 % |
50 mV |
| +12 V |
0 A |
2 A |
±5 % |
±1 % |
120 mV |
|
| -12 V |
0 A |
0.5 A |
±10 % |
±1 % |
120 mV |
* Load step ±40 % related to 60 % load
** Input voltage jump ±10 % at rated load
Max. output power must not exceed 70 W. Ripple and noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 0.47 µF ceramic capacitor at each output. For connection to a low voltage mains supply an additional input filter may be required.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.