You are here: Bicker Elektronik / Products / DC/DC converters / BES-307CT

BES-307CT

70 Watt

  • 18…56 VDC input range
  • Operating temperature 0…+50 °C
  • Installation height only 38 mm

The widerange input voltage of 18…56 VDC provided by the DC/DC converter BES-307CT includes the typical voltages 24 V, 28 V, 36 V and 48 V. It was especially developed for industrial and mobile computer systems with low power requirements. The possible fields of application for the BES-307CT are enlarged further by its compact design and fanless operation.

Technical data

 

Input voltage

18…56 VDC

Input current

4 A (+48 V)

Inrush current

<15 A at +25 °C

Efficiency

>70 % at rated load

Protection

Short circuit protection: At each output, auto-recovery
Overvoltage protection: +5 V (5.7…7 V), Switch off
Inverse-polarity protection: diode at input

Insulation voltage

Input / Chassis 1000 VAC
Input / Output 2828 VAC

Operating temperature

0…+50 °C

MTBF

247 000 h according to MIL-HDBK-217F at +50 °C

Storage temperature

-20…+70 °C

Operating humidity

10…90 % RH, non-condensing

Dimensions

134 x 84 x 38 mm ±0.8 mm

Weight (net)

0.4 kg

Article
No.

Output
voltage

Output current
min

Output current
 max

Load
regulation*

Line
regulation**

Ripple &
Noise

BES-307CT

+5 V

1 A

12 A

±1 %

±1 %

50 mV

+12 V

0 A

2 A

±5 %

±1 %

120 mV

-12 V

0 A

0.5 A

±10 %

±1 %

120 mV

* Load step ±40 % related to 60 % load
** Input voltage jump ±10 % at rated load
Max. output power must not exceed 70 W. Ripple and noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 0.47 µF ceramic capacitor at each output. For connection to a low voltage mains supply an additional input filter may be required.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.

Technical documentation: