You are here: Bicker Elektronik / Products / DC/DC converters / BEC-100-12VCF

BEC-100-12VCF

100 Watt

  • Operating temperature -20…+70 °C
  • Compact Design
  • Widerange input

The compact DC/DC converter BEC-100-12VCF was designed for supplying displays for mobile applications. With its widerange input this DC/DC converter operates both in 12 V DC and 24 V DC vehicle voltages. The output voltage is galvanically isolated from the input and regulated. Cooling for the BEC-100-12VCF is done either by means of a heatsink or optionally by an extension to the casing.

Technical data

 

Input voltage

10…36 VDC

Input current

13 A max (10 VDC), 5.5 A max. (24 VDC)

Efficiency

App. 80 %

Protection

Short circuit protection: yes, auto-recovery
Overtemperature protection: Switch off at app. +100 °C (chassis temperature), auto-recovery

Insulation voltage

1500 VDC Input / Output

Safety

Designed according to EN60950

Operating temperature

-20…+70 °C

Derating

Depending on ambient operating temperature, load and cooling

Cooling

For fanless operation at + 50 °C a heatsink with a thermal resistance of ≤2 K / W is required.

Temperature coefficient

±0.03 % / °C

MTBF

900 000 h at +25 °C according to MIL-HDBK-217F

Storage temperature

-40…+85 °C

Operating humidity

10…90 % RH, non-condensing

Dimensions

98 x 86 x 28 mm ±0.8 mm (without heatsink)

Weight (net)

0.15 kg

Product-specific data

Adjustable range

Output voltage ±10 %, adjustable at R2

On / Off function

X2 PIN7,8, ON if X2 is not connected
open = On / bridged = Off

Article
No.

Output
voltage

Output current
min

Output current
 min

Ripple &
Noise

BEC-100-12VCF

+12 V

0 A

8.3 A

150 mV

Ripple and noise was measured by a 15 MHz bandwidth limited oscilloscope with connected 10 nF Tantalum capacitor and 1 µF ceramic capacitor at each output.
As a power component this PSU is for assembly purposes only and must not be operated in unassembled condition. The final assembly has to comply with the valid EMC and safety standards.

BEC-100-12VCF bottom view

BEC-100-12VCF,
Bottom view of BEC-100-12VCF
Technical documentation: